10k ntc 3950热敏电阻(温度/阻值R/T对照表)及应用指南

来源:
2021-06-17 返回列表




10K 3950 NTC热敏电阻传感器采用高精度NTC芯片加工而成,可靠的NTC热敏电阻和合格的导线制造而成,采用绝缘、导热,防水材料包裹成所需形状,便于长/短距离的测温,控制和安装。

 

产品特征:

  • 响应快速

  • 耐高温

  • 安装方便

  • 防水,防腐蚀等

  • 良好的防水性能

  • 耐用性,寿命长


规格参数:

10k ntc 3950热敏电阻(温度/阻值R/T对照表)
B值(R25 / R50)3950K
阻值@R2510 KΩ
公差值1%
工作范围   -30〜105℃
头部尺寸环氧涂层
Φ3,Φ4,Φ5,或定制
导线PVC电缆
长度定制
连接器XH-2P


10k ntc 3950热敏电阻R/T表

标称阻值:10k Ohms at 25deg. C

阻值精度:+/-5%

B值: 3950K at 25/50 deg. C

B值精度: +/-1%


温度最小阻值标称阻值最大阻值
(deg. C)(Ω Ohms)(Ω Ohms)(Ω Ohms)
-40373804.6343632.6315106.2
-39349255.3321280.9294808.3
-38326483.9300533.9275954.9
-37305349.9281266258434
-36285725.2263362.4242142.9
-35267492.5246717.7226987.5
-34250544.2231235.5212881.3
-33234781.8216827.3199745.2
-32220114.7203411.8187506.3
-31206460.2190914.4176097.8
-30193741.9179266.6165458.1
-29181889.9168405.3155530.6
-28170839.9158272.6146263.3
-27160532.5148815.1137608.2
-26150913.4139983.7129521.1
-25141932.3131733.2121961.2
-24133543.2124021.6114891
-23125703.3116810.7108275.8
-22118373.5110064.8102083.5
-21111517.4103751.296284.6
-20105101.697839.690851.7
-1999095.29230285759.6
-1893469.687112.480984.7
-1788198.482247.176505.5
-1683257.377683.772302
-1578623.673401.868355.4
-1474276.369382.364648.7
-1370196.265607.761165.8
-1266365.262061.657891.9
-1162766.658728.854813.3
-1059385.155595.351917.2
-956206.35264849191.6
-853216.849874.746625.7
-750404.347264.344209.1
-647757.444806.241932.3
-545265.342490.639786.3
-442918.140308.637763.1
-340706.638251.635854.7
-238622.136311.734054.1
-136656.734481.732354.6
034802.932754.730749.9
133053.731124.329234.3
231402.729584.727802.2
329843.728130.126448.7
428371.226755.625168.9
526979.925456.223958.5
625664.924227.422813.3
724421.52306521729.4
823245.52196520703.2
922132.920923.919731.4
1021079.81993818810.8
1120082.919004.117938.4
1219138.718119.317111.4
1318244.317280.716327.1
1417396.716485.715583.3
1516593.315731.714877.5
1615831.515016.414207.7
1715108.914337.613571.8
1814423.313693.312967.8
1913772.613081.612394.2
2013154.912500.511849
2112568.311948.511330.9
2212011.111423.910838.3
2311481.610925.210369.8
2410978.4104519924.1
2510500100009500
2610053.99570.99088.4
279629.19162.68696.8
289224.68773.88324.3
298839.38403.77969.7
308472.18051.27632.1
318122.27715.47310.6
327788.67395.37004.4
337470.57090.36712.7
3471676799.56434.6
356877.66522.16169.6
366601.36257.65916.9
376337.66005.15675.8
386085.85764.25445.9
395845.45534.25226.5
405615.75314.65017.1
415396.35104.94817.1
425186.54904.54626.2
434986.147134443.8
444794.445304269.6
4546114355.14103.1
464435.74187.83944
474267.94027.83791.8
484107.33874.83646.3
493953.63728.33507.2
503806.43588.23374
513665.534543246.6
523530.53325.53124.7
533401.13202.53007.9
543277.23084.62896.1
553158.42971.72789.1
563044.52863.52686.5
572935.32759.72588.2
582830.52660.32494
5927302564.92403.7
602633.62473.42317.1
612541.12385.62234.1
622452.32301.42154.5
6323672220.62078.1
642285.12143.12004.8
652206.52068.61934.4
662130.919971866.9
672058.41928.31802
681988.61862.31739.7
691921.61798.91679.9
701857.117381622.5
711795.11679.41567.2
721735.51623.11514.2
731678.21568.91463.1
7416231516.81414.1
751569.91466.71366.9
761518.81418.51321.5
771469.71372.21277.9
781422.31327.51235.9
791376.71284.51195.5
801332.81243.11156.6
811290.51203.31119.2
821249.71164.91083.1
831210.51127.91048.4
841172.61092.31015
851136.11058982.8
861100.91024.9951.7
871067993921.8
881034.3962.3893
891002.8932.6865.2
90972.3904838.4
91942.9876.4812.6
92914.6849.8787.7
93887.2824.1763.6
94860.8799.4740.4
95835.3775.4718.1
96810.7752.3696.5
97786.9730675.6
98763.9708.5655.5
99741.7687.7636.1
100720.2667.6617.3
101699.5648.2599.2
102679.5629.5581.7
103660.1611.3564.8
104641.4593.8548.4
105623.2576.9532.6
106605.7560.5517.3
107588.8544.7502.6
108572.4529.3488.3
109556.5514.5474.5
110541.2500.2461.2
111526.3486.3448.3
112511.9472.9435.8
113498459.9423.7
114484.5447.4412
115471.5435.2400.7
116458.9423.4389.7
117446.6412379.1
118434.7400.9368.8
119423.3390.2358.9
120412.1379.9349.3
121401.3369.8339.9
122390.9360.1330.9
123380.7350.6322.1
124370.9341.5313.7
125361.4332.6305.4
126352.1324297.5
127343.1315.7289.7
128334.4307.6282.2
129326299.8275
130317.8292.2267.9
131309.9284.8261.1
132302.2277.6254.5
133294.7270.7248
134287.4264241.8
135280.4257.4235.7
136273.5251.1229.9
137266.9244.9224.2
138260.4238.9218.6
139254.1233.1213.3
140248227.4208
141242.1222203
142236.3216.6198.1
143230.7211.4193.3
144225.3206.4188.6
145220201.5184.1
146214.9196.8179.7
147209.9192.2175.5
148205187.7171.3
149200.3183.3167.3
150195.7179.1163.4
151191.3174.9159.6
152186.9170.9155.9
153182.7167152.3
154178.6163.2148.8
155174.6159.5145.4
156170.7155.9142.1
157166.9152.4138.9
158163.2149135.8
159159.6145.7132.7
160156.1142.5129.7
161152.7139.4126.9
162149.4136.3124
163146.2133.3121.3
164143130.4118.6
165140127.6116.1
166137124.9113.5
167134.1122.2111.1
168131.2119.6108.7
169128.5117106.3
170125.8114.6104.1
171123.2112.1101.9
172120.6109.899.7
173118.1107.597.6
174115.7105.395.6
175113.3103.193.6
17611110191.6
177108.898.989.7
178106.696.987.9
179104.494.986.1
180102.39384.3
181100.391.182.6
18298.389.380.9
18396.487.579.3
18494.585.877.7
18592.684.176.2
18690.882.474.6
1878980.873.2
18887.379.271.7
18985.677.770.3
1908476.268.9
19182.474.767.6
19280.873.366.3
19379.371.965
19477.870.563.8
19576.469.262.5
19674.967.961.4
19773.566.660.2
19872.265.459.1
19970.964.258
20069.66356.9